Background: Anterior cervical discectomy and fusion (ACDF) is widely used for treating degenerative cervical disc disease. Porous trabecular titanium (PTT), manufactured by electron beam melting (EBM) technology, has demonstrated excellent osteogenic and osteoinductive potential in vitro, but in vivo performance remains unclear.
Methods: This level IIb, prospective cohort study included 26 patients undergoing one- to three-level ACDF using patented 3D EBM-printed PTT cages modelled by CAD/CAM technology. Primary outcome was fusion rate at 3 months, assessed by CT. Secondary outcomes included VAS pain scores and the Neck Disability Index (NDI) at 3, 6, 12, and 24 months.
Results: Single-level fusion was performed in 14 patients (54%), two-level fusion in 9 patients (35%), and three-level fusion in 3 patients (11%). At the 3-month CT scan 18 (72%) patients showed radiographic signs of new bone formation (Goldschlager grade ≥1), of these, 8 patients (32%) had continuous bridging bone (grade 2) meeting the study’s pre-specified definition of fusion, while 10 patients (40%) showed non-continuous new bone (grade 1), At the 6-month follow-up, plain radiographs suggested fusion in 96% of patients. Mean radicular and axial VAS pain scores improved by 83% and 81%, respectively. Mean NDI scores improved by 76%. Fusion rates and clinical outcomes did not differ between patients undergoing different numbers of operated levels.
Conclusions: 3D-EBM-printed porous trabecular titanium cages in ACDF were associated with early radiographic signs of osseointegration on CT at 3 months, and with apparent fusion on plain radiographs in the large majority of patients by 6 months, together with significant improvements in disability and pain scores. Larger, controlled studies are needed to confirm these early findings.
References
- Al-Mefty O, Harkey LH, Middleton TH, Smith RR, Fox JL. Myelopathic cervical spondylotic lesions demonstrated by magnetic resonance imaging. J Neurosurg. 1988;68:217–22. doi: 10.3171/jns.1988.68.2.0217.
- Benzel EC, Lancon J, Kesterson L, Hadden T. Cervical laminectomy and dentate ligament section for cervical spondylotic myelopathy. J Spinal Disord. 1991;4:286–95. doi: 10.1097/00002517-199109000-00005.
- Mastronardi L, Roperto R, Cacciotti G, Calvosa F. Anterior Cervical Fusion with Stand-alone Trabecular Metal Cages to Treat Cervical Myelopathy Caused by Degenerative Disk Disease. Observations in 88 Cases with Minimum 12-month Follow-up. J Neurol Surg A Cent Eur Neurosurg. 2018;79(6):496-501. doi: 10.1055/s-0038-1642008.
- Samartzis D, Shen FH, Goldberg EJ, An HS. Is autograft the gold standard in achieving radiographic fusion in one-level anterior cervical discectomy and fusion with rigid anterior plate fixation? Spine (Phila Pa 1976) 2005;30:1756–61. doi: 10.1097/01.brs.0000172148.86756.ce.
- Shapiro S, Connolly P, Donnaldson J, Abel T. Cadaveric fibula, locking plate, and allogeneic bone matrix for anterior cervical fusions after cervical discectomy for radiculopathy or myelopathy. J Neurosurg 2001;95:43–50. doi: 10.3171/spi.2001.95.1.0043.
- Wilke HJ, Kettler A, Claes L. Primary stabilizing effect of interbody fusion devices for the cervical spine: an in vitro comparison between three different cage types and bone cement. Eur Spine J 2000;9:410–6. doi: 10.1007/s005860000168.
- Heary RF, Parvathreddy N, Sampath S, Agarwal N. Elastic modulus in the selection of interbody implants. J Spine Surg 2017;3:163–7. doi: 10.21037/jss.2017.05.01.
- Hanc M, Fokter SK, Vogrin M, Molicnik A, Recnik G. Porous tantalum in spinal surgery: an overview. Eur J Orthop Surg Traumatol 2016;26:1–7. doi: 10.1007/s00590-015-1654-x.
- Wigfield CC, Nelson RJ. Nonautologous interbody fusion materials in cervical spine surgery: how strong is the evidence to justify their use? Spine (Phila Pa 1976) 2001;26:687–94. doi: 10.1097/00007632-200103150-00027.
- Moreland DB, Asch HL, Clabeaux DE, Castiglia GJ, Czajka GA, Lewis PJ, et al. Anterior cervical discectomy and fusion with implantable titanium cage: initial impressions, patient outcomes and comparison to fusion with allograft. Spine J 2004;4:184–91. doi: 10.1016/j.spinee.2003.05.001.
- Suchomel P, Barsa P, Buchvald P, Svobodnik A, Vanickova E. Autologous versus allogenic bone grafts in instrumented anterior cervical discectomy and fusion: a prospective study with respect to bone union pattern. Eur Spine J 2004;13:510–5. doi: 10.1007/s00586-003-0667-z.
- Thomé C, Krauss JK, Zevgaridis D. A prospective clinical comparison of rectangular titanium cages and iliac crest autografts in anterior cervical discectomy and fusion. Neurosurg Rev 2004;27:34–41. doi: 10.1007/s10143-003-0297-2.
- Caliogna L, Bina V, Botta L, Benazzo FM, Medetti M, Maestretti G, et al. Osteogenic potential of human adipose derived stem cells (hASCs) seeded on titanium trabecular spinal cages. Sci Rep 2020;10:18284. doi: 10.1038/s41598-020-75385-y.
- Yue W-M, Brodner W, Highland TR. Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5- to 11-year radiologic and clinical follow-up study. Spine (Phila Pa 1976) 2005;30:2138–44. doi: 10.1097/01.brs.0000180479.63092.17.
- Papacci F, Rigante L, Fernandez E, Meglio M, Montano N. Anterior cervical discectomy and interbody fusion with porous tantalum implant. Results in a series with long-term follow-up. J Clin Neurosci 2016;33:159–62. doi: 10.1016/j.jocn.2016.03.036.
- Levine BR, Sporer S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials 2006;27:4671–81. doi: 10.1016/j.biomaterials.2006.04.041.
- Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br 1999;81:907–14. doi: 10.1302/0301-620x.81b5.9283.
- Siu TL, Rogers JM, Lin K, Thompson R, Owbridge M. Custom-Made Titanium 3-Dimensional Printed Interbody Cages for Treatment of Osteoporotic Fracture-Related Spinal Deformity. World Neurosurg 2018;111:1–5. doi: 10.1016/j.wneu.2017.11.160.
- Goldschlager T, Rosenfeld JV, Ghosh P, Itescu S, Blecher C, McLean C, et al. Cervical interbody fusion is enhanced by allogeneic mesenchymal precursor cells in an ovine model. Spine (Phila Pa 1976) 2011;36:615–23. doi: 10.1097/BRS.0b013e3181dfcec9.
- Barsa P, Suchomel P. Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion. Eur Spine J 2007;16:1395–400. doi: 10.1007/s00586-006-0284-8.
- Wu W-J, Jiang L-S, Liang Y, Dai L-Y. Cage subsidence does not, but cervical lordosis improvement does affect the long-term results of anterior cervical fusion with stand-alone cage for degenerative cervical disc disease: a retrospective study. Eur Spine J 2012;21:1374–82. doi: 10.1007/s00586-011-2131-9.
- Zajonz D, Franke A-C, von der Höh N, Voelker A, Moche M, Gulow J, et al. Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring. Patient Saf Surg 2014;8:43. doi: 10.1186/s13037-014-0043-4.
- Fernández-Fairen M, Alvarado E, Torres A. Eleven-Year Follow-Up of Two Cohorts of Patients Comparing Stand-Alone Porous Tantalum Cage Versus Autologous Bone Graft and Plating in Anterior Cervical Fusions. World Neurosurg 2019;122:e156–67. doi: 10.1016/j.wneu.2018.09.160.
- Nau AM, Naidoo N, Nau T. The orthopedic surgeon’s guide to statistics: interpreting research with confidence. Muscles, Ligaments and Tendons Journal 2025;15:121–9. doi: 10.32098/mltj.02.2025.01.
- Padulo J, Oliva F, Frizziero A, Maffulli N. Muscles, Ligaments and Tendons Journal - Basic principles and recommendations in clinical and field Science Research: 2016 Update. Muscles Ligaments Tendons J 2016;6:1–5. doi: 10.11138/mltj/2016.6.1.001.
- Tomé-Bermejo F, Morales-Valencia JA, Moreno-Pérez J, Marfil-Pérez J, Díaz-Dominguez E, Piñera AR, et al. Degenerative Cervical Disc Disease: Long-term Changes in Sagittal Alignment and Their Clinical Implications After Cervical Interbody Fusion Cage Subsidence: A Prospective Study With Standalone Lordotic Tantalum Cages. Clin Spine Surg 2017;30:E648–55. doi: 10.1097/BSD.0000000000000293.
- King V, Swart A, Winder MJ. Tantalum trabecular metal implants in anterior cervical corpectomy and fusion: 2-year prospective analysis. J Clin Neurosci 2016;32:91–4. doi: 10.1016/j.jocn.2016.03.026.
- Kasliwal MK, Baskin DS, Traynelis VC. Failure of porous tantalum cervical interbody fusion devices: two-year results from a prospective, randomized, multicenter clinical study. J Spinal Disord Tech 2013;26:239–45. doi: 10.1097/BSD.0b013e318241e70f.
- Löfgren H, Engquist M, Hoffmann P, Sigstedt B, Vavruch L. Clinical and radiological evaluation of Trabecular Metal and the Smith-Robinson technique in anterior cervical fusion for degenerative disease: a prospective, randomized, controlled study with 2-year follow-up. Eur Spine J 2010;19:464–73. doi: 10.1007/s00586-009-1161-z.
- Fernández-Fairen M, Sala P, Dufoo M, Ballester J, Murcia A, Merzthal L. Anterior cervical fusion with tantalum implant: a prospective randomized controlled study. Spine (Phila Pa 1976) 2008;33:465–72. doi: 10.1097/BRS.0b013e3181657f49.
- Benazzo F, Botta L, Scaffino MF, Caliogna L, Marullo M, Fusi S, et al. Trabecular titanium can induce in vitro osteogenic differentiation of human adipose derived stem cells without osteogenic factors. J Biomed Mater Res A 2014;102:2061–71. doi: 10.1002/jbm.a.34875.
- Tamaddon M, Samizadeh S, Wang L, Blunn G, Liu C. Intrinsic Osteoinductivity of Porous Titanium Scaffold for Bone Tissue Engineering. Int J Biomater 2017;2017:5093063. doi: 10.1155/2017/5093063.
- Gastaldi G, Caliogna L, Botta L, Ghiara M, Benazzo F. Endothelial Progenitor Cell Adhesion, Growth and Characterization on Trabecular Titanium and Trabecular Titanium Coated with Collagen or Decellularized ECM. J Biol Regul Homeost Agents 2015;29:15–24.
- Fraser JF, Härtl R. Anterior approaches to fusion of the cervical spine: a metaanalysis of fusion rates. J Neurosurg Spine 2007;6:298–303. doi: 10.3171/spi.2007.6.4.2.
- Epstein NE. A Review of Complication Rates for Anterior Cervical Diskectomy and Fusion (ACDF). Surg Neurol Int 2019;10:100. doi: 10.25259/SNI-191-2019.
- Bell KM, Bechara BP, Hartman RA, Shively C, Frazier EC, Lee JY, et al. Influence of number of operated levels and postoperative time on active range of motion following anterior cervical decompression and fusion procedures. Spine (Phila Pa 1976) 2011;36:263–8. doi: 10.1097/BRS.0b013e3181ccc552.
- Patel MS, McCormick JR, Ghasem A, Huntley SR, Gjolaj JP. Tantalum: the next biomaterial in spine surgery? J Spine Surg 2020;6:72–86. doi: 10.21037/jss.2020.01.01.
- Sink EL, Leunig M, Zaltz I, Gilbert JC, Clohisy J, Academic Network for Conservational Hip Outcomes Research Group. Reliability of a complication classification system for orthopaedic surgery. Clin Orthop Relat Res 2012;470:2220–6. doi: 10.1007/s11999-012-2343-2.
- Brantigan JW, Steffee AD. A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine (Phila Pa 1976) 1993;18:2106–7. doi: 10.1097/00007632-199310001-00030.
- Lenke LG, Bridwell KH, Bullis D, Betz RR, Baldus C, Schoenecker PL. Results of in situ fusion for isthmic spondylolisthesis. J Spinal Disord 1992;5:433–42. doi: 10.1097/00002517-199212000-00008.