DOI: 10.32098/mltj.03.2020.09

In Vivo Assessment of the Tensor Vastus Intermedius Cross-sectional Area Using Ultrasonography

Authors

  • C. Sahinis Laboratory of Neuromechanics, Department of Physical Education and Sport Sciences at Serres, Aristotle University of Thessalonica, Serres, Greece
  • E. Kellis Laboratory of Neuromechanics, Department of Physical Education and Sport Sciences at Serres, Aristotle University of Thessalonica, Serres, Greece
  • A. Ellinoudis Laboratory of Neuromechanics, Department of Physical Education and Sport Sciences at Serres, Aristotle University of Thessalonica, Serres, Greece
  • K. Dafkou Laboratory of Neuromechanics, Department of Physical Education and Sport Sciences at Serres, Aristotle University of Thessalonica, Serres, Greece

ekellis@phed-sr.auth.gr

Keywords

Quadriceps, architecture, ultrasound, tensor of vastus intermedius, muscle function

Abstract

Background. There is growing evidence that the quadriceps muscle group includes a fifth head, the tensor of vastus intermedius (TVI). The purpose of this study was to quantify the anatomic cross-sectional area (CSA) of the TVI using ultrasound.

Methods. Ultrasonography scans were taken from 21 young males and females at rest, at 0° (= full extension), 45° and at 90° of knee flexion and they were repeated a week after to establish reliability. Measurements of the CSA were obtained from the most proximal and the most distal part of the muscle belly and from three different parts toward the course of the tendon.

Results. US evaluation of the CSA displayed high reliability with an intraclass coefficient (ICC3,3) ranging from 0.85 to 0.99 and a standard error of measurement ranging from 0.0019 to 0,2789 mm2. Analysis of variance indicated that the TVI muscle belly was larger proximally than distally and it was smaller at full extension compared with greater flexion angles (p < 0.05). The tendon CSA was greater proximally than middle and distal measurement sites (p <0.05) but it did differ between various knee flexion angles.

Conclusions. Future studies on the quadriceps muscle function and morphology should include examination of the TVI.

View the entire article

Downloads

This article was originally published by Edra S.p.A. and is made available here as part of the Muscles, Ligaments and Tendons Journal archive. Its inclusion in the current Journal archive does not alter the copyright, licensing, or reuse terms applicable at the time of its original publication.

Published

2020-09-30

How to Cite

1.
Sahinis C, Kellis E, Ellinoudis A, Dafkou K. In Vivo Assessment of the Tensor Vastus Intermedius Cross-sectional Area Using Ultrasonography. MLTJ [Internet]. 2020 Sep. 30 [cited 2026 Nov. 19];10(3). Available from: https://mltj.online/index.php/mltj/article/view/7209