DOI: 10.32098/mltj.03.2019.12

Does the 5-strand-graft have superior biomechanical behaviour than 4-strand-graft during ACL reconstruction?

Authors

  • D. Pavan Department of Orthopaedic Surgery, University of Palermo (Di.Chir.On.S), Palermo, Italy
  • G. Pitarresi Department of Industrial and Digital Innovation (DIID) Chemical, Management, Computer, Mechanical Engineering, Viale delle Scienze ed.8, I-90128 Palermo
  • F. Morello Department of Orthopaedic Surgery, University of Palermo (Di.Chir.On.S), Palermo, Italy
  • F. Monachino Department of Orthopaedic Surgery, University of Palermo (Di.Chir.On.S), Palermo, Italy
  • A. Sanfilippo Department of Orthopaedic Surgery, University of Palermo (Di.Chir.On.S), Palermo, Italy
  • A. D’Arienzo Department of Orthopaedic Surgery, University of Pisa, Pisa, Italy
  • L. Camarda Department of Orthopaedic Surgery, University of Palermo (Di.Chir.On.S), Palermo, Italy

lawrence.camarda@unipa.it

Keywords

4-strand-graft, 5-strand-graft, ACL reconstruction, graft, graft diameter, knee biomechanics

Abstract

Purpose. This study aimed to compare the biomechanical proprieties of 4 and 5-strandgrafts.

Methods. For the present study, fresh-frozen bovine common digital extensor tendons were used. Tendon grafts were prepared and sized to have a length of almost 27 cm and a cylinder 4 strand diameter of 8 mm. In half of all samples (Group A, n=12), the graft was formed by 2 bundles duplicated around a metallic rod creating a 4-strand-tendon construct. In the other half of samples (Group B, n= 12,) 5-strand-tendon construct was created duplicating a single tendon around the rod, and tripling the other one. The grafts were preconditioned at 50 N for 10 min, followed by 1,000 cyclic loading between 50 and 250 N. Load-to-failure test was then carried out at a rate of 1 mm/s.

Results. No statistically significant differences were found between two groups concerning cyclic elongation at the 500th cycle and at the final cycle. An increased stiffness was observed in the Group B during cyclic loads and at pull-out (p<0.05). Significant differences were noted at the ultimate load-to-failure between Group A (1533 ± 454 N) and Group B (1139 ± 276 N) (p< 0.05).

Conclusion. This study showed that both graft construct appears to be biomechanically effective in a bovine tendon model. 5-strand-graft showed an increased stiffness and a decreased ultimate load-to-failure comparing to the 4-strand-graft construct. Biomechanically, no real benefit could be observed in the clinical setting increasing the numbers of strands used for the ACL reconstructive surgery.

View the entire article

Downloads

Published

2019-09-30

How to Cite

1.
Pavan D, Pitarresi G, Morello F, Monachino F, Sanfilippo A, D’Arienzo A, et al. Does the 5-strand-graft have superior biomechanical behaviour than 4-strand-graft during ACL reconstruction? MLTJ [Internet]. 2019 Sep. 30 [cited 2026 Nov. 20];9(3). Available from: https://mltj.online/index.php/mltj/article/view/7157

Most read articles by the same author(s)