DOI: 10.32098/mltj.03.2019.07

Healing of partial-thickness rotator cuff tears following arthroscopic augmentation with a highly-porous collagen implant: a 5-year clinical and MRI follow-up

Authors

  • D. J. Bokor Faculty of Medicine and Health Sciences, Macquarie University, Australia
  • D. H. Sonnabend Department of Orthopaedic Surgery, Royal North Shore Hospital, St. Leonards, Australia
  • L. Deady Alfred Imaging & Alfred Advanced Sports Imaging Centre, Drummoyne, Australia
  • B. Cass Sydney Shoulder Specialists, St. Leonards, Australia
  • A. A. Young Sydney Shoulder Specialists, St. Leonards, Australia
  • C. L. Van Kampen Smith & Nephew, Plymouth, Minnesota, USA
  • S. P. Arnoczky College of Veterinary Medicine Michigan State University, East Lansing, USA

desbok@iinet.net.au

Keywords

Arthroscopic shoulder surgery, collagen implant, rotator cuff tears, surgical treatment, tendon healing

Abstract

Background. The purpose of this study was to review patients with intermediate- and high-grade partial-thickness rotator cuff tears at 5 years following insertion of a highly- porous collagen implant on the bursal surface of the cuff to determine the durability of the clinical results and structural integrity of the healed tendons compared to their previously reported 2-year results.

Methods. Eleven of the original 13 patients were examined after 5 years. Clinical scores (Constant and ASES) and MRI evaluations of tendon integrity and quality were compared to the two-year results.

Results. All patients demonstrated statistically significant improvement in clinical scores compared to preoperative values. Mean Constant and ASES pain and function scores improved at 5 years but were not statistically different from the two-year scores. Eight of the 11 patients demonstrated no negative change in tendon quality on MRI. However, 3 patients had developed new, asymptomatic tears (1 low-grade articular, 2 low-grade intra-substance) of the supraspinatus tendon.

Conclusions. This 5-year follow-up confirms the ongoing clinical benefit of this implant in the treatment of partial-thickness lesions of the rotator cuff and demonstrates ongoing structural tendon improvement, with most repaired tendons intact at five years.

View the entire article

Downloads

Published

2019-09-30

How to Cite

1.
Bokor DJ, Sonnabend DH, Deady L, Cass B, Young AA, Van Kampen CL, et al. Healing of partial-thickness rotator cuff tears following arthroscopic augmentation with a highly-porous collagen implant: a 5-year clinical and MRI follow-up. MLTJ [Internet]. 2019 Sep. 30 [cited 2026 Nov. 19];9(3). Available from: https://mltj.online/index.php/mltj/article/view/7152