DOI: 10.32098/mltj.01.2022.07

The A1 Pulley as a Fulcrum for Flexor Tendon Excursion: a Histopathological Study

Authors

  • A. Mor Department of Orthopedics, Hasharon Hospital, Rabin Medical Campus, Petach Tiqwa, Israel
  • E. Behrbalk Department of Orthopedics, Hillel Yaffe Medical Center, Hadera, Israel
  • S. Ikher Department of Pathology, Kaplan Medical Center, Rehovot, Israel
  • M. Vigler Department of Orthopedics, Hasharon Hospital, Rabin Medical Campus, Petach Tiqwa, Israel
  • A. Oron Department of Orthopedics, Kaplan Medical Center, Rehovot, Israel

eyalbehrbalk@gmail.com

Keywords

A1 pulley, excursion, flexor tendon, fulcrum, histopathological

Abstract

Purpose. Stenosing tenosynovitis of the flexor tendons which readily causes the alleged “trigger finger” is a common and yet not completely understood phenomenon. The A1 Pulley is the pivot point at which the force protracted by the flexors of the digits acts upon the fulcrum at the leading edge of the pulley. We performed a histopathological study aimed at assessing the A1 Pulley of digits 2 through 5 in cadaver hands in an effort to delineate the changes the A1 pulley undergoes through the cycle of life and its repetitive motion tasks.

Methods. Thirty-Nine A1 Pulley specimens were included in the study. These specimens were assessed as to physical width utilizing a caliper and as to histological characteristics following embedment and pertinent staining.

Results. Our findings suggest the proximal leading edge of the A1 Pulley to be significantly (p < 0.05) thicker than the more distal aspect of the A1 pulley when pulley data were stratified for handedness and gender. We found insignificant differences within each digit as to differences between the radial and ulnar aspects of the denoted numerated digit.

Conclusions. We believe our study sheds further light on the mechanism leading to digital triggering and that further studies may substantiate our preliminary findings as to the differences in radial versus ulnar aspects of each designated digital A1 pulley.

View the entire article

Downloads

This article was originally published by Edra S.p.A. and is made available here as part of the Muscles, Ligaments and Tendons Journal archive. Its inclusion in the current Journal archive does not alter the copyright, licensing, or reuse terms applicable at the time of its original publication.

Published

2026-04-16

How to Cite

1.
Mor A, Behrbalk E, Ikher S, Vigler M, Oron A. The A1 Pulley as a Fulcrum for Flexor Tendon Excursion: a Histopathological Study. MLTJ [Internet]. 2026 Apr. 16 [cited 2026 Nov. 20];12(1). Available from: https://mltj.online/index.php/mltj/article/view/6795