Inter-rater Reliability of Sports Medicine Physicians to Assess Healthy Individuals’ Patellar Tendon with Conventional Ultrasound and Shear-wave Elastography

Authors

  • S. Devran Department of Sports Medicine, Faculty of Medicine, Istanbul University, Istanbul, Turkey
  • S. Dincer Department of Sports Medicine, Faculty of Medicine, Istanbul University, Istanbul, Turkey
  • O. Ekiz Department of Sports Medicine, Faculty of Medicine, Istanbul University, Istanbul, Turkey
  • O. Pasin Department of Biostatistics, Faculty of Medicine, Bezmialem University, Istanbul, Turkey
  • B. Bayraktar Department of Sports Medicine, Faculty of Medicine, Istanbul University, Istanbul, Turkey

sergendevran@istanbul.edu.tr

Keywords

patellar tendon, power doppler, shear wave elastography, sports medicine, ultrasound

Abstract

To evaluate the reproducibility of shear-wave elastography, thickness, power doppler, and hypoechoic region assessments taken from the different parts of the patellar tendon among sports medicine clinicians.
Twenty-one healthy, physically active individuals with dominant legs were included in the study. Shear-wave elastography, thickness, power doppler, and hypoechoic area assessment were evaluated from the proximal, middle, and distal part of the tendon both at 30-degree knee flexion and full extension. To evaluate the reproducibility within and among clinicians, the same measurements were performed at 4-7 days intervals.
Evaluations of intra- and inter-rater reliability for examiners I and II were conducted via two-way random effects and absolute agreement type intraclass correlation coefficient (ICC). Gwet’s AC1 (GC) agreement coefficient was used to evaluate categorical data agreement.
The intra-rater reliability of both sports physicians on shear-wave elastography was in good to excellent reproducibility in all three parts at the 0–30-degree measurements (intra-observer ICC: 0.60-0.88, inter-observer ICC: 0.67-0.87). Similar results were obtained for the thickness (intra-observer ICC: 0.83-0.94, inter-observer ICC: 0.65-0.83). As a result of the power doppler taken at two different angles were excellently (intra-observer GC: 0.86-1.00, inter-observer GC: 0.86-1.00) consistent both within and among the clinicians but not for the hypoechoic region evaluation (intra-observer GC: 0.58-1.00, inter-observer GC: 0.40-1.00).
This study shows that the reproducibility of local measurements made in different parts of the patellar tendon at two different angles within and among sports medicine physicians is at a good to an excellent level.

View the entire article

Downloads

This article was originally published by Edra S.p.A. and is made available here as part of the Muscles, Ligaments and Tendons Journal archive. Its inclusion in the current Journal archive does not alter the copyright, licensing, or reuse terms applicable at the time of its original publication.

Published

2022-09-30

How to Cite

1.
Devran S, Dincer S, Ekiz O, Pasin O, Bayraktar B. Inter-rater Reliability of Sports Medicine Physicians to Assess Healthy Individuals’ Patellar Tendon with Conventional Ultrasound and Shear-wave Elastography. MLTJ [Internet]. 2022 Sep. 30 [cited 2026 Nov. 19];12(3). Available from: https://mltj.online/index.php/mltj/article/view/6738