DOI: 10.32098/mltj_2026_6708

Biomechanical Analysis of Rotator Cuff Repair Utilizing the Tendon-to-Bone Seam Technique

Authors

  • Jacob J. Triplet Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, Indiana University Health, Muncie, USA
  • Howard W. Harris Shoulder Specialist, Texas Orthopedic Specialists, Bedford, USA
  • Patrick M. Connor Shoulder and Elbow Center, Sports Medicine Center, OrthoCarolina, Charlotte, USA
  • Michael Q. Freehill Shoulder Care Specialists, Summit Orthopedics, Eagan, USA
  • Scott W. Trenhaile Sports Medicine Specialists, OrthoIllinois, Rockford, USA
  • Stephen P. Wiseman OhioHealth Orthopedic Surgeons, Grant Medical Center, Columbus, USA
  • Marc R. Labbè Houston Methodist Orthopedics and Sports Medicine, Woodlands Hospital, The Woodlands, USA

jacob.john.triplet@gmail.com

Keywords

Rotator cuff, biomechanical, trans-osseous, double row, single row, tendon seam

Abstract

Aim: To report the biomechanical performance of a novel “Tendon-to-Bone Seam” (TBS) rotator cuff repair technique and compare the results to those previously obtained with knotted and knotless transosseous-equivalent (TOE) constructs using similar protocols to assess relative performance.
Materials and methods: Eleven fresh-frozen human cadaveric shoulders underwent creation of full-thickness supraspinatus tears (approximately 2.0–3.0 cm). All specimens were repaired using the TBS technique by one of four fellowship-trained shoulder surgeons, utilizing a mattress-stitch pattern medially and a zig-zag pattern laterally. Repairs were tested using a mechanical test system under cyclic loading from 10–180 N for 30 cycles and 4–302 N for 500 cycles, followed by load-to-failure testing. Gap formation, yield strength, and ultimate strength were measured and compared with prior TOE repair data.
Results: Gap formation for the TBS repair technique was 0.30 ± 0.47 mm after 1 cycle and 0.33 ± 0.55 mm after 30 cycles at 180 N. After 500 cycles at 302 N, gap formation was 0.90 ± 1.03 mm. Yield strength was 600.70 ± 93.60 N with corresponding gap formation of 1.21 ± 1.26 mm. Ultimate strength was 747.80 ± 153.80 N with corresponding gap formation of 1.68 ± 1.45 mm.
Conclusions: Rotator cuff repair utilizing the TBS repair technique demonstrated reduced gap formation and increased fatigue, yield, and ultimate strength as compared to prior biomechanical cadaveric studies evaluating the TOE repair. Moreover, the strength of the TBS repair technique exceeds the maximal force the supraspinatus and infraspinatus rotator cuff muscles can generate.

View the entire article

Downloads

References

  1. Karjalainen TV, Jain NB, Heikkinen J, Johnston RV, Page CM, Buchbinder R. Surgery for rotator cuff tears. Cochrane Database Syst Rev. 2019;12(12):CD013502. doi: 10.1002/14651858.CD013502.
  2. Sambandam SN, Khanna V, Gul A, Mounasamy V. Rotator cuff tears: An evidence based approach. World J Orthop. 2015;6(11):902-918. doi: 10.5312/wjo.v6.i11.902.
  3. Collin P, Kempf JF, Molé D, et al. Ten-Year Multicenter Clinical and MRI Evaluation of Isolated Supraspinatus Repairs. J Bone Joint Surg Am. 2017;99(16):1355-1364. doi: 10.2106/JBJS.16.01267.
  4. Colvin AC, Egorova N, Harrison AK, Moskowitz A, Flatow EL. National trends in rotator cuff repair. J Bone Joint Surg Am. 2012;94(3):227-233. doi: 10.2106/JBJS.J.00739.
  5. Moosmayer S, Lund G, Seljom U, Svege I, Hennig T, Tariq R, et al. Comparison between surgery and physiotherapy in the treatment of small and medium-sized tears of the rotator cuff: A randomised controlled study of 103 patients with one-year follow-up. J Bone Joint Surg Br. 2010;92(1):83-91. doi: 10.1302/0301-620X.92B1.22609.
  6. Haque A, Pal Singh H. Does structural integrity following rotator cuff repair affect functional outcomes and pain scores? A meta-analysis. Shoulder Elbow. 2018;10(3):163-169. doi: 10.1177/1758573217731548.
  7. Young BL, Bitzer A, Odum S, Hamid N, Shiffern S, Connor PM. Healthcare costs of failed rotator cuff repairs. JSES Rev Rep Tech. 2023;3(3):318-323. doi: 10.1016/j.xrrt.2023.03.008.
  8. Chona DV, Lakomkin N, Lott A, Workman AD, Henry AC, Kuntz AF, et al. The timing of retears after arthroscopic rotator cuff repair. J Shoulder Elbow Surg. 2017;26(11):2054-2059. doi: 10.1016/j.jse.2017.07.015.
  9. Xu C, Zhao J, Li D. Meta-analysis comparing single-row and double-row repair techniques in the arthroscopic treatment of rotator cuff tears. J Shoulder Elbow Surg. 2014;23(2):182-188. doi: 10.1016/j.jse.2013.08.005.
  10. Slabaugh MA, Nho SJ, Grumet RC, Wilson JB, Seroyer ST, Frank RM, et al. Does the literature confirm superior clinical results in radiographically healed rotator cuffs after rotator cuff repair?. Arthroscopy. 2010;26(3):393-403. doi: 10.1016/j.arthro.2009.07.023.
  11. Rossi LA, Rodeo SA, Chahla J, Ranalletta M. Current Concepts in Rotator Cuff Repair Techniques: Biomechanical, Functional, and Structural Outcomes. Orthop J Sports Med. 2019;7(9):2325967119868674. doi: 10.1177/2325967119868674.
  12. Bedeir YH, Schumaier AP, Abu-Sheasha G, Grawe BM. Type 2 retear after arthroscopic single-row, double-row and suture bridge rotator cuff repair: a systematic review. Eur J Orthop Surg Traumatol. 2019;29(2):373-382. doi: 10.1007/s00590-018-2306-8.
  13. Ruiz Ibán MÁ, García Navlet M, Moros Marco S, Diaz Heredia J, Hernando Sánchez A, Ruiz Díaz R, et al. Augmentation of a Transosseous-Equivalent Repair in Posterosuperior Nonacute Rotator Cuff Tears With a Bioinductive Collagen Implant Decreases the Retear Rate at 1 Year: A Randomized Controlled Trial. Arthroscopy. 2024;40(6):1760-1773. doi: 10.1016/j.arthro.2023.12.014.
  14. Haroun Y, Sobhy MH, Khater HA, Khater AH. Comparison between four different suture configurations for rotator cuff repair: a biomechanical animal study. SICOT J. 2024;10:39. doi: 10.1051/sicotj/2024038.
  15. Park MC, Tibone JE, ElAttrache NS, Ahmad CS, Jun BJ, Lee TQ. Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg. 2007;16(4):469-476. doi: 10.1016/j.jse.2006.09.011.
  16. Busfield BT, Glousman RE, McGarry MH, Tibone JE, Lee TQ. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots. Am J Sports Med. 2008;36(5):901-906. doi: 10.1177/0363546507312640.
  17. Ansah-Twum J, Belk JW, Cannizzaro CK, Potyk AG, Bravman JT, McCarty EC, et al. Knotted Transosseous-Equivalent Technique for Rotator Cuff Repair Shows Superior Biomechanical Properties Compared With a Knotless Technique: A Systematic Review and Meta-analysis. Arthroscopy. 2022;38(3):1019-1027. doi: 10.1016/j.arthro.2021.09.017.
  18. Burkhart SS. A stepwise approach to arthroscopic rotator cuff repair based on biomechanical principles. Arthroscopy. 2000;16(1):82-90. doi: 10.1016/s0749-8063(00)90133-6.
  19. Cho NS, Yi JW, Lee BG, Rhee YG. Retear patterns after arthroscopic rotator cuff repair: single-row versus suture bridge technique. Am J Sports Med. 2010;38(4):664-671. doi: 10.1177/0363546509350081.
  20. Hohmann E, König A, Kat CJ, Glatt V, Tetsworth K, Keough N. Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors. A systematic review and meta-analysis of basic biomechanical studies. Eur J Orthop Surg Traumatol. 2018;28(5):859-868. doi: 10.1007/s00590-017-2114-6.
  21. Wall LB, Keener JD, Brophy RH. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence. J Shoulder Elbow Surg. 2009;18(6):933-941. doi: 10.1016/j.jse.2009.07.002.
  22. Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ. Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg. 2007;16(4):461-468. doi: 10.1016/j.jse.2006.09.010.
  23. Perser K, Godfrey D, Bisson L. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair. Sports Health. 2011;3(3):268-274. doi: 10.1177/1941738111403106.
  24. Prasathaporn N, Kuptniratsaikul S, Kongrukgreatiyos K. Single-row repair versus double-row repair of full-thickness rotator cuff tears. Arthroscopy. 2011;27(7):978-985. doi: 10.1016/j.arthro.2011.01.014.
  25. Sheibani-Rad S, Giveans MR, Arnoczky SP, Bedi A. Arthroscopic single-row versus double-row rotator cuff repair: a meta-analysis of the randomized clinical trials. Arthroscopy. 2013;29(2):343-348. doi: 10.1016/j.arthro.2012.11.019.
  26. Millett PJ, Warth RJ, Dornan GJ, Lee JT, Spiegl UJ. Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials. J Shoulder Elbow Surg. 2014;23(4):586-597. doi: 10.1016/j.jse.2013.10.006.
  27. Park MC, Idjadi JA, Elattrache NS, Tibone JE, McGarry MH, Lee TQ. The effect of dynamic external rotation comparing 2 footprint-restoring rotator cuff repair techniques. Am J Sports Med. 2008;36(5):893-900. doi: 10.1177/0363546507313092.
  28. Hatta T, Giambini H, Hooke AW, Zhao C, Sperling JW, Steinmann SP, et al. Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double-Row and Knotless Transosseous-Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study. Arthroscopy. 2016;32(10):1973-1981. doi: 10.1016/j.arthro.2016.02.024.
  29. Kaplan K, ElAttrache NS, Vazquez O, Chen YJ, Lee T. Knotless rotator cuff repair in an external rotation model: the importance of medial-row horizontal mattress sutures. Arthroscopy. 2011;27(4):471-478. doi: 10.1016/j.arthro.2010.11.006.
  30. Vaishnav S, Millett PJ. Arthroscopic rotator cuff repair: scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system. J Shoulder Elbow Surg. 2010;19(2 Suppl):83-90. doi: 10.1016/j.jse.2009.12.012.
  31. Burkhart SS, Adams CR, Burkhart SS, Schoolfield JD. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair. Arthroscopy. 2009;25(3):274-281. doi: 10.1016/j.arthro.2008.09.024.
  32. Hashiguchi H, Iwashita S, Sonoki K, Abe K, Yoneda M, Takai S. Clinical outcomes and structural integrity of arthroscopic double-row versus suture-bridge repair for rotator cuff tears. J Orthop. 2018;15(2):396-400. doi: 10.1016/j.jor.2018.03.012.
  33. Kim KC, Shin HD, Lee WY, Han SC. Repair integrity and functional outcome after arthroscopic rotator cuff repair: double-row versus suture-bridge technique. Am J Sports Med. 2012;40(2):294-299. doi: 10.1177/0363546511425657.
  34. Park JY, Lee SY, Chung SW, Zulkifli H, Cho JH, Oh KS. Clinical comparison between double-row and transosseous-equivalent repairs for medium to large size rotator cuff tears. Arch Orthop Trauma Surg. 2013;133(12):1727-1734. doi: 10.1007/s00402-013-1872-9.
  35. Yu C, Sun L, Gao H, Sheng H, Feng X, Yang X, et al. Rotator cuff repair with all-suture anchor enhances biomechanical properties and tendon-bone integration in a rabbit model. Heliyon. 2024;10(18):e37707. Published 2024 Sep 13. doi: 10.1016/j.heliyon.2024.e37707.

Published

2026-09-24

How to Cite

1.
Triplet JJ, Harris HW, Connor PM, Freehill MQ, Trenhaile SW, Wiseman SP, et al. Biomechanical Analysis of Rotator Cuff Repair Utilizing the Tendon-to-Bone Seam Technique. MLTJ [Internet]. 2026 Sep. 24 [cited 2026 Nov. 19];16(3). Available from: https://mltj.online/index.php/mltj/article/view/6708